Home Back

Coefficient Of Discharge For Time Required To Lower Liquid Surface Calculator

Coefficient of Discharge Formula:

\[ C_d = \frac{2 \times A_R}{\frac{2}{3} \times \Delta t \times \sqrt{2 \times g} \times L_w} \times \left( \frac{1}{\sqrt{h_2}} - \frac{1}{\sqrt{H_{Upstream}}} \right) \]

s
m/s²
m
m
m

Unit Converter ▲

Unit Converter ▼

From: To:

1. What is the Coefficient of Discharge?

The Coefficient of Discharge (Cd) is the ratio of actual discharge to theoretical discharge in fluid flow systems. It accounts for energy losses and flow characteristics in hydraulic structures like weirs, orifices, and pipes.

2. How Does the Calculator Work?

The calculator uses the Coefficient of Discharge formula:

\[ C_d = \frac{2 \times A_R}{\frac{2}{3} \times \Delta t \times \sqrt{2 \times g} \times L_w} \times \left( \frac{1}{\sqrt{h_2}} - \frac{1}{\sqrt{H_{Upstream}}} \right) \]

Where:

Explanation: This formula calculates the discharge coefficient based on the time required to lower the liquid surface in a reservoir through a weir.

3. Importance of Coefficient of Discharge Calculation

Details: Accurate calculation of the discharge coefficient is crucial for designing hydraulic structures, predicting flow rates, and ensuring proper water management in irrigation systems, dams, and other water control facilities.

4. Using the Calculator

Tips: Enter all values in appropriate units (meters for length, seconds for time). Ensure all input values are positive and valid for accurate results.

5. Frequently Asked Questions (FAQ)

Q1: What is the typical range for Coefficient of Discharge values?
A: For most weirs, the coefficient of discharge typically ranges from 0.6 to 0.9, depending on the weir type and flow conditions.

Q2: Why is the coefficient of discharge less than 1?
A: The coefficient is less than 1 due to energy losses from friction, turbulence, and other flow disturbances that reduce the actual discharge below the theoretical ideal.

Q3: How does weir shape affect the discharge coefficient?
A: Different weir shapes (sharp-crested, broad-crested, V-notch, etc.) have different flow characteristics and thus different typical coefficient values.

Q4: When is this specific formula applicable?
A: This formula is specifically used for calculating the discharge coefficient based on the time required to lower the liquid surface in a reservoir through a weir.

Q5: What factors can affect the accuracy of the calculation?
A: Measurement accuracy of heads, time interval, and geometric dimensions, as well as assumptions about ideal flow conditions, can affect the result accuracy.

Coefficient Of Discharge For Time Required To Lower Liquid Surface Calculator© - All Rights Reserved 2025