Maximum Voltage using Resistance (1-Phase 2-Wire US) Calculator

Maximum Voltage using Resistance (1-Phase 2-Wire US) Formula:

\[ V_m = \frac{2 \cdot P \cdot \sqrt{\frac{R}{P_{loss}}}}{\cos(\Phi)} \]

Watt
Ohm
Watt
radian

Unit Converter ▲

Unit Converter ▼

From: To:

1. What is Maximum Voltage using Resistance (1-Phase 2-Wire US)?

Maximum Voltage using Resistance (1-Phase 2-Wire US) calculates the peak voltage in a single-phase two-wire underground AC system based on power transmitted, resistance, line losses, and phase difference. This is essential for proper system design and ensuring voltage levels remain within safe operating limits.

2. How Does the Calculator Work?

The calculator uses the formula:

\[ V_m = \frac{2 \cdot P \cdot \sqrt{\frac{R}{P_{loss}}}}{\cos(\Phi)} \]

Where:

Explanation: This formula calculates the maximum voltage by considering the power transmitted, system resistance, power losses, and the phase angle between voltage and current.

3. Importance of Maximum Voltage Calculation

Details: Accurate maximum voltage calculation is crucial for proper insulation selection, equipment rating, system protection design, and ensuring compliance with electrical safety standards in underground AC systems.

4. Using the Calculator

Tips: Enter power transmitted in watts, resistance in ohms, line losses in watts, and phase difference in radians. All values must be positive numbers greater than zero.

5. Frequently Asked Questions (FAQ)

Q1: Why is maximum voltage important in underground systems?
A: Maximum voltage determines insulation requirements, affects equipment sizing, and ensures system safety and reliability in underground installations.

Q2: How does resistance affect maximum voltage?
A: Higher resistance typically requires higher voltage to transmit the same power, but the relationship is complex as shown in the formula.

Q3: What is the significance of phase difference in this calculation?
A: Phase difference affects the power factor, which influences the relationship between real power, apparent power, and voltage requirements.

Q4: Are there limitations to this formula?
A: This formula assumes balanced conditions and may not account for all system complexities such as harmonic distortions or varying load conditions.

Q5: How do line losses impact maximum voltage requirements?
A: Higher line losses typically require higher transmission voltages to maintain the same power delivery at the receiving end.