Power Factor using Area of X-Section(Single phase Two Wire OS) Calculator

Power Factor Formula:

\[ PF = \sqrt{\frac{4 \times P^2 \times \rho \times L}{A \times P_{\text{loss}} \times V_m^2}} \]

Watt
Ω·m
Meter
Watt
Volt

Unit Converter ▲

Unit Converter ▼

From: To:

1. What is Power Factor?

The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. It indicates how effectively electrical power is being used.

2. How Does the Calculator Work?

The calculator uses the power factor formula:

\[ PF = \sqrt{\frac{4 \times P^2 \times \rho \times L}{A \times P_{\text{loss}} \times V_m^2}} \]

Where:

Explanation: The formula calculates power factor based on the relationship between transmitted power, line characteristics, and losses in a single-phase two-wire overhead system.

3. Importance of Power Factor Calculation

Details: Power factor calculation is crucial for efficient power system operation, reducing energy losses, optimizing equipment performance, and minimizing electricity costs in AC power distribution systems.

4. Using the Calculator

Tips: Enter all values in appropriate units. Ensure all values are positive and non-zero. The calculator will compute the power factor based on the input parameters for a single-phase two-wire overhead system.

5. Frequently Asked Questions (FAQ)

Q1: What is a good power factor value?
A: A power factor close to 1 (unity) is ideal. Values below 0.95 are generally considered poor and may require power factor correction.

Q2: How does power factor affect electricity bills?
A: Many utilities charge penalties for low power factor because it indicates inefficient use of electrical power and requires more current to deliver the same real power.

Q3: What causes low power factor?
A: Low power factor is typically caused by inductive loads like motors, transformers, and fluorescent lighting that require reactive power.

Q4: How can power factor be improved?
A: Power factor can be improved by adding capacitors or synchronous condensers to supply reactive power, reducing the reactive power drawn from the source.

Q5: What are the limitations of this calculation?
A: This calculation assumes ideal conditions and may not account for all real-world factors like temperature variations, harmonic distortions, or non-linear loads.