Home Back

Shunt Adjustable Resistance For Series Type Ohmmeter Calculator

Formula Used:

\[ R2 = \frac{If \times Rh \times Rm}{E - (If \times Rh)} \]

Ampere
Ohm
Ohm
Volt

Unit Converter ▲

Unit Converter ▼

From: To:

1. What is Shunt Adjustable Resistance For Series Type Ohmmeter?

The Shunt Adjustable Resistance for Series Type Ohmmeter refers to a variable resistor used to calibrate or adjust the zero reading of a measuring instrument. It plays a crucial role in ensuring accurate resistance measurements in series-type ohmmeters.

2. How Does the Calculator Work?

The calculator uses the formula:

\[ R2 = \frac{If \times Rh \times Rm}{E - (If \times Rh)} \]

Where:

Explanation: This formula calculates the zero adjusting resistance required to properly calibrate a series-type ohmmeter based on the instrument's electrical characteristics and power supply.

3. Importance of Zero Adjusting Resistance Calculation

Details: Accurate calculation of zero adjusting resistance is essential for proper calibration of ohmmeters, ensuring precise resistance measurements and maintaining the instrument's accuracy over time.

4. Using the Calculator

Tips: Enter current full scale reading in Ampere, half scale resistance in Ohm, meter resistance in Ohm, and voltage source in Volt. All values must be positive numbers.

5. Frequently Asked Questions (FAQ)

Q1: What is the purpose of zero adjusting resistance?
A: Zero adjusting resistance is used to calibrate the zero reading of a measuring instrument, ensuring accurate measurements across the entire measurement range.

Q2: Why is half scale resistance important?
A: Half scale resistance provides a reference point for calibration, typically representing the midpoint between maximum and minimum resistance values of a variable resistor.

Q3: What affects meter resistance?
A: Meter resistance is inherent to the instrument's design and construction, including the coil resistance, internal wiring, and other components that affect current flow.

Q4: When should zero adjustment be performed?
A: Zero adjustment should be performed regularly as part of instrument maintenance, whenever measurements seem inaccurate, or after significant environmental changes.

Q5: Are there limitations to this calculation?
A: This calculation assumes ideal conditions and may need adjustments for specific instrument designs, temperature variations, or other external factors affecting measurement accuracy.

Shunt Adjustable Resistance For Series Type Ohmmeter Calculator© - All Rights Reserved 2025